Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 19 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.10.8.2 Thermal
conditioning
N
2.10.8.3
Electric strength test
N
2.10.8.4
Abrasion resistance test
N
2.10.9
Thermal cycling
No special insulation in order
to reduce distance.
to reduce distance.
N
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
insulating compound
No such component.
N
2.10.11
Tests for semiconductor devices and cemented
joints
joints
No such device used.
N
2.10.12
Enclosed and sealed parts
No such part.
N
Measuring instrument
Inv. no.
Date
3
WIRING, CONNECTIONS AND SUPPLY
⎯
3.1 General
⎯
3.1.1
Current rating and overcurrent protection
Adequate cross sectional
areas on internal wiring.
areas on internal wiring.
P
3.1.2
Protection against mechanical damage
Wireways are smooth and free
from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.
from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.
P
3.1.3
Securing of internal wiring
P
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to be
of adequate quality and
suitable for the application and
the working voltage involved.
conductors is considered to be
of adequate quality and
suitable for the application and
the working voltage involved.
P
3.1.5
Beads and ceramic insulators
No beads or similar ceramic
insulators on conductors.
insulators on conductors.
N