Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 17 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.10.3.5
Clearances in circuits having starting pulses
The circuit will not generating
starting pulse.
starting pulse.
N
2.10.3.6
Transients from a.c. mains supply ........................: Considered. N
2.10.3.7
Transients from d.c. mains supply ........................: Not connected to DC mains
supply.
N
2.10.3.8
Transients from telecommunication networks and
cable distribution systems .....................................:
cable distribution systems .....................................:
Not connected to
telecommunication networks
and cable distribution
systems.
telecommunication networks
and cable distribution
systems.
N
2.10.3.9
Measurement of transient voltage levels
See below.
⎯
a) Transients from a mains suplply
Measurement not relevant.
N
For an a.c. mains supply .......................................:
N
For a d.c. mains supply .........................................:
N
b) Transients from a telecommunication network :
Not connected to
telecommunication networks.
telecommunication networks.
N
2.10.4
Creepage distances
Class III equipment.
N
2.10.4.1 General
N
2.10.4.2
Material group and caomparative tracking index
N
CTI
tests .................................................................:
⎯
2.10.4.3
Minimum creepage distances
N
2.10.5
Solid insulation
See below.
⎯
2.10.5.1 General
Considered.
P
2.10.5.2
Distances through insulation
Class III equipment.
N
2.10.5.3
Insulating compound as solid insulation
No such construction used.
N
2.10.5.4 Semiconductor
devices
No such components.
N
2.10.5.5.
Cemented joints
Not used.
N
2.10.5.6
Thin sheet material – General
Considered.
P
2.10.5.7
Separable thin sheet material
Class III equipment.
N
Number of layers (pcs)...........................................:
⎯
2.10.5.8
Non-separable thin sheet material
Not used.
N
2.10.5.9
Thin sheet material – standard test procedure
Class III equipment.
N
Electric strength test
⎯
2.10.5.10 Thin sheet material – alternative test procedure
Class III equipment.
N
Click on the first or last page to see other ON STAGE 200ID service manuals if exist.