No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
2.10.3.5 
Clearances in circuits having starting pulses 
The circuit will not generating 
starting pulse. 
2.10.3.6 
Transients from a.c. mains supply ........................: Considered. N 
2.10.3.7 
Transients from d.c. mains supply ........................: Not connected to DC mains 
supply. 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems  .....................................:
Not connected to 
telecommunication networks 
and cable distribution 
systems. 
2.10.3.9 
Measurement of transient voltage levels 
See below. 
⎯ 
 
a) Transients from a mains suplply 
Measurement not relevant. 
 
For an a.c. mains supply .......................................:  
 
For a d.c. mains supply .........................................:  
 
b) Transients from a telecommunication network : 
Not connected to 
telecommunication networks. 
2.10.4 
Creepage distances 
Class III equipment. 
2.10.4.1 General 
 
2.10.4.2 
Material group and caomparative tracking index 
 
 CTI 
tests .................................................................:  
⎯ 
2.10.4.3 
Minimum creepage distances 
 
2.10.5 
Solid insulation 
See below. 
 
2.10.5.1 General 
Considered. 
2.10.5.2 
Distances through insulation 
Class III equipment. 
2.10.5.3 
Insulating compound as solid insulation 
No such construction used. 
2.10.5.4 Semiconductor 
devices 
No such components. 
2.10.5.5. 
Cemented joints 
Not used. 
2.10.5.6 
Thin sheet material – General 
Considered. 
2.10.5.7 
Separable thin sheet material 
Class III equipment. 
 
Number of layers (pcs)...........................................:  
⎯ 
2.10.5.8 
Non-separable thin sheet material 
Not used. 
2.10.5.9 
Thin sheet material – standard test procedure 
Class III equipment. 
 
Electric strength test 
 
⎯ 
2.10.5.10  Thin sheet material – alternative test procedure 
Class III equipment. 