ON STAGE 200ID (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 20

Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online

Ident. Nr.: 
98323 
Date:  
2008-3-11 
 
98323__EMC_TRF 
page 20 of 46 
5.5.2  Diagram 007  
Operating Condition: Connect to iPod 
Test Specification:  Horizontal & Vertical 
Comment:             AC 230V/50Hz                              
 
 
5.5.3 Table 008 
Test Mode 
Emission 
Frequency 
MHz 
E-Field Polarity 
Measured Level 
dB
μV/m 
Limit 
dB
μV/m 
TM1 172.008  V 
36.0 
40 
TM1 220.501  H 
33.3 
40 
TM2 46.112  V 
32.8  40 
TM2 20.040  V 
32.0  40 
 
The emissions don’t show are too low against the limits, the test curves are shown above. 