Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 21 of 46
6 Harmonic
current
6.1 Standard
Basic standard
EN 61000-3-2:2006
Date of testing
2008.2.28
6.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008 5001ix-CTS-400
SB2588
CI
Three Phase Harmonic
flicker test system
flicker test system
February 20, 2008 PACS-3
SB2588/01 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/02 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/03 CI
6.3 Test set-up
See annexe B
See annexe B
6.4 Classification of EUT
Devices with an active input power
of P < 50 W
of P < 50 W
Balanced three-phase equipment and all other
equipment, expect that stated in one of the
following classes
equipment, expect that stated in one of the
following classes
Class A
Portable tools
Class B
Lightning equipment, including dimming devices
Class C
Equipment having an input current with a "special
wave shape" as defined in figure 1 in the
standard and an active input power, P
wave shape" as defined in figure 1 in the
standard and an active input power, P
≤ 600 W
and motor driven with phase angle control
Class D
6.5 Harmonic current measurements
Steady state:
One time window equals 16 x 20 ms is measured and evaluated
Fluctuation:
A measurement time of 2,5 min is necessary for fluctuating
harmonics, one time window equals 16 x 20 ms, therefore during a
time of 2,5 min 469 time windows are measured and evaluated.
harmonics, one time window equals 16 x 20 ms, therefore during a
time of 2,5 min 469 time windows are measured and evaluated.
Continuous measurement:
A continuous measurement session is a long time measurement,
where always the last actual 2,5 min data is stored an evaluated in
real time. Each 320 ms a new data window is acquired and the oldest
is erased. If measured values are over the limit the measurement
stops automatically.
where always the last actual 2,5 min data is stored an evaluated in
real time. Each 320 ms a new data window is acquired and the oldest
is erased. If measured values are over the limit the measurement
stops automatically.