ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
3) Tested model: MU15-C060250-C5
Transformer (T1)
Vrms Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak
Pri. pins
Sec. Pins
1 2 3 4
A
196 364 237 436 208 324 208 332
B
194 336 242 440 209 324 208 332
4) Tested model: MU15-C240010-C5
Transformer (T1)
Vrms Vpeak Vrms Vpeak Vrms Vpeak Vrms Vpeak
Pri. pins
Sec. Pins
1 2 3 4
A
197 376 211 464 210 328 210 324
B
193 332 218 480 209 328 209 328
5) The max. working voltages measured between CY1 pin 1 and CY1 pin 2: 324 V peak / 209 V rms.
6) The max. working voltages:
Measured between U2 primary pin 3 and U2 secondary pin 1: 352 V peak / 211 V rms.
Measured between U2 primary pin 4 and U2 secondary pin 1: 352 V peak / 209 V rms.
Measured between U2 primary pin 3 and U2 secondary pin 2: 352 V peak / 209 V rms.
Measured between U2 primary pin 4 and U2 secondary pin 2: 352 V peak / 209 V rms.
Measured between U2 primary pin 3 and U2 secondary pin 2: 352 V peak / 209 V rms.
Measured between U2 primary pin 4 and U2 secondary pin 2: 352 V peak / 209 V rms.