Read JBL ON CALL (serv.man2) EMC - CB Certificate online
Page 17 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
3
WIRING, CONNECTIONS AND SUPPLY
3.1 General
3.1.1
Current rating and overcurrent protection
(see appended table 1.5.1)
P
3.1.2
Protection against mechanical damage
Smooth wireways
P
3.1.3
Securing of internal wiring
All internal wirings are suitable
fixed
fixed
P
3.1.4
Insulation of conductors
P
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
No screws are used as
electrical connections
electrical connections
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
No such screws are used
N/A
3.1.9
Termination of conductors
The termination of conductors
are hooked and soldered with
the plug pins, others are
soldered to PCB
are hooked and soldered with
the plug pins, others are
soldered to PCB
P
10 N pull test
P
3.1.10
Sleeving on wiring
No sleeving used as
supplementary insulation
supplementary insulation
N/A
3.2
Connection to an a.c. mains supply or a d.c. mains supply
3.2.1
Means of connection .......................................... : Integral plug forming as part of
the equipment
P
3.2.1.1
Connection to an a.c. mains supply
A mains plug that is part of
direct plug-in equipment
direct plug-in equipment
P
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
There is only one supply
connection for the EUT
connection for the EUT
N/A
3.2.3
Permanently connected equipment
The EUT is not such types
N/A
Number of conductors, diameter (mm) of cable
and conduits ....................................................... :
and conduits ....................................................... :
3.2.4 Appliance
inlets
N/A