ON BEAT XTREME (serv.man8) - JBL Audio EMC - CB Certificate (repair manual). Page 101

Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online

Page 15 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Annex B 
5th paragraph - add reference to clause 4.2.1.1 in 
 IEC 62151. 
Add to 12th paragraph: “The requirements of 
4.2.1.1 shall be replaced by the requirements or 
2.3.1 of UL 60950, Third Edition.” 
13th paragraph, 2nd dash replace with: “In the 
event of a single insulation fault, the voltages on  
the TNV-0 circuits, TNV-1 circuits and accessible 
conductive parts shall not exceed the values given 
in clause 9.1.1.1a of this standard for more than  
0.2 s. Moreover, the limits values as given in 11.1 
shall not be exceeded. After 0.2 s the voltage limits 
of 4.1.2 (35 V peak, or 60 V d.c.) shall apply.” 
Add to 19th paragraph: “Apparatus intended to be 
connected to telecommunication networks and  
having ringing voltages applied to the apparatus is 
subjected to touch current limits in accordance with
 clause 5.1.8.1.1 of UL 60950, Third Edition” Add to
 21st paragraph: “Telecommunication network that 
uses outside cable shall comply with the requireme
nts for protection against overvoltage from power  
line crosses per 6.4 of UL 60950,  
Third Edition”  Add to 22nd paragraph: “Acoustic  
tests per 6.5 of UL 60950, Third Edition for  
apparatus containing earphone held against the  
ear.”  
Add to 24th paragraph: “Apparatus shall be 
provided with appropriate markings and instructions 
as described 
in Annex NAA of UL 60950, Third Edition.” 
Not connected to telecom 
networks. 
N/A 
Annex D 
Figure D.1 & Note delete reference to IEC 60990 
and add reference to ANSI C101.  
Add touch current value in MIU where MIU = U2 x 2 
(r.m.s. value) 
Noted 
N/A 
Annex G 
Deleted 
 
N/A 
Annex Q 
Add: Safety requirements for video apparatus for 
use in health care facilities 
Not health care 
N/A 
Annex R 
Add: Safety requirements for undercabinet 
apparatus 
Not under cabinet 
N/A 
Annex S 
Add: Safety requirements for in-wall mounted 
apparatus 
Not in wall mount 
N/A 