Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Table 20 
Add values for horizontal force test 
 
N/A 
19.6. 
Add: “or equipment rack mounting”. 
 
N/A 
20.1a Delete 
 
N/A 
20.1b 
Replace “IEC 60707” with “UL 94” 
Add: “-parts such as protection TV lenses,  
loudspeaker parts, external accessories, and  
fibrous materials less then 0.25 mm thick.” 
Noted 
N/A 
20.1.2 
Revise text to read: “Sleeving, extruded tubing and
insulation on wiring shall be rated VW-1 under 
following conditions:  
a) wiring located in a circuit that is considered a  
potential ignition source” or  
b) wiring not located in a circuit that is a potential  
ignition source but is in contact with wiring located 
in a circuit that is a potential ignition source.  
”Tape should be flame retardant.”  
Delete Note and add: “Tape in contact with parts  
of circuits that are potential ignition sources shall  
be flame retardant. 
Considered 
20.1.3 
Replace 1st paragraph with:  
“Base material of printed wiring boards, on which 
the available power as the connection exceeds  
15 W or the operating voltage exceeds 50 V a.c.  
or d.c under normal operating conditions, shall be 
of flammability category V-1 or better according 
to UL 94.”  
 
In 2nd paragraph replace “IEC 60707” with “UL 94”
and remove exception for printed boards housed  
in metal enclosures. 
 
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G. 
Pcb V-1 
20.1.4 
Replace with: “Components and parts shall comply
with the relevant flammability category according 
to UL 94 as specified in Table 21.  
Delete all other text. 
Parts meet table 21. 
Add: “Component power supplies complying with 
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are considered
to fulfill the test requirements on the clause.” 
No component power supplies 
N/A 