Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 12 of 16
Report No.: 171153
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Table 20
Add values for horizontal force test
N/A
19.6.
Add: “or equipment rack mounting”.
N/A
20.1a Delete
N/A
20.1b
Replace “IEC 60707” with “UL 94”
Add: “-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.”
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.”
Noted
N/A
20.1.2
Revise text to read: “Sleeving, extruded tubing and
insulation on wiring shall be rated VW-1 under
following conditions:
a) wiring located in a circuit that is considered a
potential ignition source” or
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source.
”Tape should be flame retardant.”
Delete Note and add: “Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
insulation on wiring shall be rated VW-1 under
following conditions:
a) wiring located in a circuit that is considered a
potential ignition source” or
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source.
”Tape should be flame retardant.”
Delete Note and add: “Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
Considered
P
20.1.3
Replace 1st paragraph with:
“Base material of printed wiring boards, on which
the available power as the connection exceeds
15 W or the operating voltage exceeds 50 V a.c.
or d.c under normal operating conditions, shall be
of flammability category V-1 or better according
to UL 94.”
In 2nd paragraph replace “IEC 60707” with “UL 94”
and remove exception for printed boards housed
in metal enclosures.
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G.
“Base material of printed wiring boards, on which
the available power as the connection exceeds
15 W or the operating voltage exceeds 50 V a.c.
or d.c under normal operating conditions, shall be
of flammability category V-1 or better according
to UL 94.”
In 2nd paragraph replace “IEC 60707” with “UL 94”
and remove exception for printed boards housed
in metal enclosures.
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G.
Pcb V-1
P
20.1.4
Replace with: “Components and parts shall comply
with the relevant flammability category according
to UL 94 as specified in Table 21.
Delete all other text.
with the relevant flammability category according
to UL 94 as specified in Table 21.
Delete all other text.
Parts meet table 21.
P
Add: “Component power supplies complying with
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are considered
to fulfill the test requirements on the clause.”
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are considered
to fulfill the test requirements on the clause.”
No component power supplies
N/A
Click on the first or last page to see other ON BEAT XTREME (serv.man8) service manuals if exist.