ON BEAT RUMBLE (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 6

Read JBL ON BEAT RUMBLE (serv.man3) EMC - CB Certificate online

Report No.:
 
EM201200813-7 
                       
Application No.:
 
ZJ00024740  
                  
Page 6 of 47
 
 
3. LABORATORY AND ACCREDITATIONS  
3.1 LABORATORY 
The tests and measurements in this report except Input Immunity was performed by EMC 
Laboratory of Guangzhou GRG Metrology and Test CO., LTD. 
         Add. 
  :    163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China 
         Telephone:   +86-20-38699959, 38699960, 38699961 
Fax 
  :   +86-20-38695185 
Input Immunity was performed by CGEL, Guangzhou EMC Laboratory. 
3.2 ACCREDITATIONS 
Our laboratories are accredited and approved by the following approval agencies according to 
ISO/IEC 17025. 
 
USA 
FCC Listed Lab No. 688188 
China 
CNAS NO.L0446 
China 
DILAC No.DL175 
Canada 
Registration No.:8355A-1 
 
3.3 MEASUREMENT UNCERTAINTY 
Where relevant, the following measurement uncertainty levels have been estimated for tests 
performed on the EUT as specified in CISPR 16-4-2: 
Measurement 
Frequency 
Uncertainty 
Radiated 
Emission 
Horizontal 
30MHz~1000MHz 
3.2dB 
Vertical 
30MHz~1000MHz 
3.6dB 
Conducted Emission 
9kHz~30MHz 
2.4 dB 
This uncertainty represents an expanded uncertainty factor of k=2. 
 