HTPS 300 (serv.man4) - JBL Audio Service Manual (repair manual). Page 9

Read JBL HTPS 300 (serv.man4) Service Manual online

8
THX Powered Subwoofer
HT PS300
short pins 6 & 7 and observe the output shuts
down within 2 seconds. Remove short and
amplifier output should return. Turn OFF and
remove R185 resistor to restore full 350 second
delay.
5. FINAL CHECKS
After repair, inspect for possible safety hazards,
including loose hardware, missing lock washers, correct
fuses and lead dress of primary wires (these must be held in
position with cable ties so that they cannot touch secondary
components).
With ohmmeter, check that panel is
connected to signal ground.
Re-attach speaker wires (if removed) to satellite PCB’s,
RED or YELLOW wires on OUT terminals; BLACK or BLUE
connected to ground terminals on main PCB.
Reinstall
amplifier in cabinet using reverse procedure in section 3.
It is essential that the following safety insulation test be
performed prior to returning the Power Sub-Woofer to the
customer, using one of the following methods with power
switch ON:
A) Insulation Resistance Test
With a 500VDC Insulation Tester, Check
insulation from the outer metal contact of the
RCA jack (chassis) to the line neutral of AC
cord. Resistance should be >100M
.
B) Hi-Pot Test
If a UL approved Hi-Pot tester is available, test
line & neutral of AC cord to outer shell of RCA
jack (chassis) at 1100VAC for 2 seconds.
Observe all of instrument manufacturer's
instructions and safety warnings in performing
this test.
Connect sub-woofer system to a music source. Play at
high level while checking for air leaks around panel edge,
driver, panel jacks and controls, and listen for voice coil
problems such as rubbing buzzing or any unusual sounds.
With the crossover "frequency" set to 50Hz, very little of the
voice content should be heard.
6. LIST OF SAFETYCOMPONENTS
REQUIRING EXACT REPLACEMENTS
F1
120VAC input units: Fuse, 4A/250V, 3AG
1/4 x 1-1/4 NORMAL BLOW, UL & CSA
approved.
230VAC input units: Fuse, 2A 250V, 3AG
5mm x 20mm, IEC127 approved.
F2-F5 Fuse, 4A/250V, 3AG 1/4 x 1 1/4 NORMAL
BLOW, UL & CSA approved
TM1
Thermostat, Open on Rise, 60
°
C, 15
°
C
hysteresis, 10A 240VAC, UL and CSA
approved. 230VAC version must also be VDE
approved for Class II circuits.
SELCO OA-140-QCV or equal for 120VAC, or
ELMWOOD P/N for 230VAC.
T1
POWER TRANSFORMER, CLASS B(130
°
C)
INSULATION, UL & CSA approved. Order
from factory, quoting model number, serial and
rated AC voltage.
230VAC version must also
meet IEC 65 requirements
R22, R75
Resistor 3R3, 1/3W, Metal Film,
Fusible, Non Flammable
Philips CR25, P/N 2322 211 3338
Philips NFR25, P/N 2322 205 3338
R140
Resistor 220R, 1/4W Metal film,
Fusible, Non-Flammable
Philips NFR25, P/N 2322 205 3221
Line Cord
For 120VAC, use SPT-2 or better,
with polarized plug, UL and CSA
marked and approved. Connect "HOT"
side (phase) to fused side, and neutral
(wider pin) to "N" pad on PCB. Use
cable ties to dress AC wires so that
they cannot touch PCBassembly or
parts. A UL/CSA approved panel strain
relief, Heyco 1127 (UL/CSA SR-4L-4) or
equal, is required.
For 230VAC versions, follow electrical
code requirement for country of
installation.
Page of 29