HTPS 300 (serv.man4) - JBL Audio Service Manual (repair manual). Page 7

Read JBL HTPS 300 (serv.man4) Service Manual online

6
THX Powered Subwoofer
HT PS300
I) Replacing power transistors: Clip all 3 leads
near body of transistor. Remove screw and
discard device (keep hardware and insulator).
Holding each lead in turn with needle nose
pliers, gently heat and remove cut lead from
hole in edge or PCB.
Clean insulator and seating area on back of
panel. Coat both sides of insulator with silicon
(white) thermal compound (unless silicone
rubber pads are provided), position it centered
on back of device with holes aligned. Insert
leads into PCBthen place pair over hole in
panel; ensure hole in insulator is aligned. Insert
screw from far side, pass shoulder bushing over
screw and carefully seat shoulder in hole in tab,
add flat washer, lock washer and nut (finger
tight). Center insulator tighten screw first then
solder all three leads in respective slots with full
fillet, being careful not to bridge pads. Use
ohmmeter to verify there is no short from tab of
transistor to panel, or between pads. See also
section (E.,XI page 7) below.
II) Removing PC assembly
(only if absolutely
necessary): Remove eight screws in power
transistors. Remove pot knobs and panel nuts.
Remove ten screws attaching signal jack
cluster, high level input supporting brackets and
PCA (Printed Circuit Assembly) from outside of
panel. Carefully lift PCA away from panel,
lifting power transistors with small screwdriver if
needed. Leave sealing gasket in place on back
of PCA; When reinstalling the assembly, make
sure this foam gasket completely seals all
around its periphery.
Never operate amplifier with load connected
when PC assembly is not attached to panel or
when any of output transistors is not properly
screwed to panel.
E) If fuse is not blown, and no obvious faults are
identified above, proceed cautiously as follows after
reading and understanding instructions as well as
warnings above, and identifying hazardous line
voltage areas on assembly from component locator
drawings (if you are unsure, consult the
manufacturer before energizing):
I) Connect lab audio oscillator (with output level
at zero) to Low Level Inputs, both Right and
Left. Use Y-cable if necessary. Set Line/THX
switch to "Line". Set amplifier "output level"
control fully clockwise, "crossover" to 60Hz.
Place unit with panel and knobs down on a
clean, convenient area of bench so that it is not
necessary to reach across amplifier to access
test equipment. Use foam blocks to hold
securely prevent rocking or damage to panel.
Tests for Channel 1 or 2 (Outputs identical)
II) Connect negative lead of DVM to either
negative output terminal near the center of the
main PCB. Use an insulated probe for the
positive lead to probe various test points.
Refer to the Printed Circuit Board Diagram on
Page 16 for test point locations/ Take care not
to short the probe to adjacent points on the
circuit board. Alternately, unplug both output
wires to woofer and connect to these points:
darker colored output wire (blue or black) is
negative.
III) Position a switched “power bar” with the
switch in a convenient location near the edge
of the bench well away form the unit so that it
can be reached safely to turn AC power ON
and OFF to unit without risk of accidental
contact with exposed areas of assembly.
See Safety Warnings in Preface.
With "bar" switch OFF, plug amplifier cord into
this controlled "power bar".
IV) Observing appropriate safety procedures, turn
"bar" ON.
With DVM probe, test following voltages:
+V
+50VDC
±
10%
-V
-50VDC
±
10%
A+
+15VDC
±
10%
A-
-15VDC
±
10%
If any of these is incorrect, switch OFF and
investigate power supply.
V) If DC is OK, check:
Speaker "OUT" tab
0VDC
±
0.03V
collector tab of Q6
25VDC
(+V
÷
2)
collector tab of Q5
-25VDC
(-V
÷
2)
Troubleshoot power amplifier if not correct.
VI) Turn AC OFF. After 60 seconds connect
oscilloscope ground probe to either negative
output terminal near the center of the main
PCB. Connect the positive scope probe to the
OUT terminal on the smaller driver board.
Refer to the Printed Circuit Board Diagram on
Page 16 for test point locations. Set the
oscilloscope controls to 20V/div. (DC) and
50msec/div. No load is needed.
VII) Turn AC ON. Set oscillator for about 42Hz sine
wave and raise output level. Observe output of
Page of 29
Display

Click on the first or last page to see other HTPS 300 (serv.man4) service manuals if exist.