1. PRINCIPLES OF OPERATION
Basic Bulk DC of
±50
V nominal is rectified by bridge D1
from the 76AVC center-tapped winding of T1. The primary
of T1 is protected by an embedded, non resettable
thermostat, a 4A, 250V fuse (2A for 230V input) F1 (in clips
on the PCB), and panel thermostat TM1. Resistors R1-R6
and zener diode D2 and D5 provide auxiliary ±15V DC for
the low level signal processing circuits.
In non-THX mode, the pair of low level signal inputs are
summed at U1b together with attenuated and inverted
(U1A) high level inputs. The feedback gain control, R95,
closely approximates a logarithmic characteristic.
The
adjustable low pass section U2Bcombines with the fixed
section U3A to attenuate high frequencies at an ultimate
slope of -36dB/octave to minimize voice content in the
sub-woofer.
Selector switch SW2 chooses either the above
(processed) inputs or a fixed-again direct "THX" input to
pass on though the first stage of speaker EQ (U5A) to
phase selection (U5B) and then to the fixed two EQ stages
(U4A & U4B). R144 is factory preset to compensate for
small variations in woofer efficiencies to meet THX
calibration and should only be readjusted if the drivers are
changed and the shop has proper equipment and
experience to carry out the procedure.
U8Band U8A continually monitor +V and -V
respectively for their minimum values which automatically
adjust the threshold for the signal peak detectors U9B(+)
and U9A (-) which in turn control the onset of AGC
compression by J-FET (voltage - controlled resistor) Q20.
U10A provides linearizing feedback to Q20, while U7Band
U10Bgenerate out-of-phase signals for the two power
amps with optional negative output impedance if
components associated with speaker current sense
resistors R160 & R154.
Each power amplifier includes U1 feedback amplifier,
class A level shifter Q1-Q4 and complementary Darlington
buffer Q5-Q6. FET Q7 in series with Q6 sustains half of the
rail-to-output voltages, as does Q8 for Q5 (with
quasi-complementary driver Q9).
The amplifier also contain an "auto mute" circuit which
silences the amplifier after a signal absence of about 6
minutes. U6Bamplifies level inputs by 40dBfor threshold
comparator U6A. U11 is a retriggerable one-shot formed
from a 16 stage counter and an oscillator of about 93 HZ
which times out about 6 minutes after the last signal input is
detected by U6A.
Some models also contain an LED
indicator DS1B(showing that the amplifier is enabled)
driven by current source Q19. The versions, a second LED
DS1C is illuminated in "stand by" by Q21, and on others, a
dual color DS1A/DS1Bcombines the modes.
The balanced bridges R205, R206, R207 & R211 and
R208, R212 & R213, inverter U3Band Schmitt trigger
Q23-24 detect the blowing of any of the amplifier fuses
(F2-F5) and force counter U11 to flash the LED’s at about
0.5 Hz to alert the user to the need for service.
2. TROUBLE SHOOTING BEFORE OPENING
Check connections, control settings, driver and other
possible external problems. If there is Output, determine if
all controls and Inputs function properly. Rotate Pots over
full range while applying lateral and vertical oscillating
forces to locate possible intermittent function. High Level
Inputs should be tested individually both differentially
(signal from "-" to "+" with normal output) and in common
mode (signal from low level ground to both "+" and "-"
shorted together, giving virtually no output). While passing
a signal, corner drop the enclosure a few inches to expose
possible intermittent problems. Check woofer for rubbing of
voice coil or tears in cone or surround. Check cabinet for
loose extraneous articles which may have been pushed
into rear port. If LED(s) are flashing at about 0.5Hz, then
one or more of the internal fuses are blown.
3. REMOVING THE AMPLIFIER
This amplifier has a power switch. Hazardous voltages
are present within the unit whenever it is plugged in. This
still applies when the over-temperature thermostat opens.
BEFORE THIS AMPLIFIER IS PLUGGED IN, make sure its rated voltage corresponds to the voltage of the AC power
source to be employed. Failure to use the correct voltage could cause damage to the amplifier when the AC power cable is
plugged in. Do not exceed the rated voltage by more than 10%; operation below 90% will degrade performance or cause the
unit to shut off.