Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.6 
Switches 
     
 
(See list of critical components) 
14.6.1 Permanently 
connected 
equipment 
provided 
with 
an all-pole mains switch unless 5.4.2 is met 
 N 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................... :
No, “ timer “ function  
 
Switch readily accessible and not in mains cord 
 
 Exception 
for 
automatic 
switching 
Yes 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
ON N 
 
Indication by marking meets Cl. 5 
AC POWER 
 Indication 
of 
the 
OFF 
position 
OFF 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................ :
No N 
 
Stand-by mode clearly discernible ........................ :  
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 N 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
C1 P 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
SW 1  
(Peak surge current = 36A) 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 N 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N 