ESC Xcite - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL ESC Xcite EMC - CB Certificate online

 
 
page 9 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test 
Weight 14 kg 
12.1.2 
Vibration test 
No connection or part, which 
might impair safety, can 
become loose.    
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ..................... :
Fuse holder (Prim.)  – accessible 
metal part = >15 mm  
13.1.1 
Reduction applied if the 3 conditions are met  ....... : No 
 
Reduction applied for Grade 2 winding wire  ......... : No 
13.1.2 
Use of cemented joints .......................................... : No 
 
Tests to confirm cemented joints 
 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ....................................... :
5 mm 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
 
Page of 46