Read JBL ESC Xcite EMC - CB Certificate online
page 12 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category FV 1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.5
Protective
devices
(See list of critical components)
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
Thermal Cut-out not activated
during the tests.
during the tests.
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices resettable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
Mains fuse
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Mains fuse: T4AL,
Secondary fuses:
F901 and F902: T8H
F903 and F904: T1.6AL
F905: T2AL
F906 and F907: T4AL
F901 and F902: T8H
F903 and F904: T1.6AL
F905: T2AL
F906 and F907: T4AL
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required.
P
14.5.3
PTC-S thermistors comply with IEC 60738
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
Click on the first or last page to see other ESC Xcite service manuals if exist.