Read JBL ES 250PW EMC - CB Certificate online
Page 13 of 48
Report No. 806703
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Iron core is floating inside the
transformer (toroidal transf)
transformer (toroidal transf)
N/A
Coil formers and partition walls = 0.4 mm
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
ST-22 (in TT0930505270-E) N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
A4-5A-F (in 150-R1107012A-E)
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ...: Fuse T 2.5A L/250V
P
14.5.2.3
Not possible to connect fuses in parallel ................:
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A