ES 250PW - JBL Audio EMC - CB Certificate (repair manual). Page 15

Read JBL ES 250PW EMC - CB Certificate online

 
Page 12 of 48 
Report No. 806703 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
14 COMPONENTS 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 Resistors 
separately approved ...............................:   
N/A 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ...:  Y1: C03, C04 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ...:  X2: C01, C02 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ......................: 
 
N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better .......................................................................: 
C01, C02 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier per Table 21..........................: No 
N/A 
14.3 
Inductors and windings 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
Transtec TT0930505270-E alt. 
Zhong Shan Yi Qi  
150-R1107012A-E
 
 
Transformers and inductors separately approved .:  No 
N/A 
14.3.2 
General 
14.3.3, 14.3.4.1 and 14.3.5.1 
14.3.3 
Constructional requirements (complete appended tables or include manufacturers 
constructional insulation descriptions) 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 Transformers 
meet 
the 
constructional requirements   
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Primary – secondary distances:
TT0930505270-E: 17mm 
150-R1107012A-E: 10mm 
 
Coil formers and partition walls = 0.4 mm 
 
N/A 
Page of 63
Display