LC-37GA9EK (serv.man7). Software Updating - Sharp TV Service Manual (repair manual)

Model
LC-37GA9EK (serv.man7)
Pages
10
Size
4.62 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Software Updating
File
lc-37ga9ek-sm7.pdf
Date

View Sharp LC-37GA9EK (serv.man7) Service Manual online

22
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
SOFTWARE UPDATING 
There are 3 methods to update software in the VCTp: I2C method, RS-232C HyperTerminal and RS-232C Tera Term 
method.
· 
RS-232C method is allowed when the TV is working properly and the action should be only software upgrade.
· 
I2C method is required when the VCTp flash is empty or corrupted (it means, any software inside IC running).
1. RS-232C Method Description (HyperTerminal).
The hardware tools requirement are:
1. A Modem-null (Cross type) DB9 female to DB9 female cable.
2. An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ)
3. Make the connections as indicated in the figure:
Before using RS-232C updating method is necessary to configure a Terminal PC software. HyperTerminal has been 
selected as a Terminal software because it’s include in all Windows versions as an accessory, and you can find it inside 
“Accessories\Communications” folder. For this reason, please follow carefully the next steps:
1. First time HyperTerminal is used, it’s necessary to configure some settings. Follows next action to configure two
    connection: low speed (9600bps) and high speed (115200bps).
2. Create a New Connection file with name “P55_9600bps”.
3.  Select a free COM port  and select the Port Settings properties as follows:
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set
23
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
4. Click on “File\Properties” menu for selecting the General and ASCII properties as follows:
5. Select “New Connection” in the File Menu.
6. Answer “Yes” to close current connection and “Yes” to save session “P55_9600bps”.
7. Create a new connection with the name “P55_115200bps”.
8. Select a the same COM port  used in item 2 and select the Port Settings properties as follows:
9. Select the same General and ASCII properties as item 3.
10.  Close  HyperTerminal  session,  answering  “Yes”  to  close  current  connection  and  “Yes”  to  save  session
       “P55_115200bps”.
To start updating session, click over “P55_9600bps” icon that you can find in the “START\All programs\Accessories\
Communications\HyperTerminal\HyperTerminal” folder and follow next procedure:
1. Check the connection between TV set and PC, sending a wrong command, as for example: “aaa”. TV set returns
    an “ERR” label as an syntaxis ERROR (Not correct order or sequence).
4.  Click  on  “File\Properties”  menu  for  selecting  the  General  and  ASCII  properties  as 
follows:
5.  Select “New Connection” in the File Menu. 
6.  Answer “Yes” to close current connection and “Yes” to save session “P55_9600bps”. 
7.  Create a new connection with the name “P55_115200bps”. 
8.  Select a the same COM port  used in item 2 and select the Port Settings properties as 
follows:
9.  Select the same General and ASCII properties as item 3. 
10. Close Hyperterminal session, answering “Yes” to close current connection and “Yes” to 
save session “P55_115200bps”. 
�� To start updating session, click over “P55_9600bps” icon that you can find in the “START\All 
programs\Accessories\Communications\HyperTerminal\HyperTerminal”  folder  and  follow  next 
procedure:
1.  Check  the  connection  between  TV  set  and  PC,  sending  a  wrong  command,  as  for 
example: “aaa”. TV set returns an “ERR” label as an syntaxis ERROR (Not correct order 
or sequence). 
4.  Click  on  “File\Properties”  menu  for  selecting  the  General  and  ASCII  properties  as 
follows:
5.  Select “New Connection” in the File Menu. 
6.  Answer “Yes” to close current connection and “Yes” to save session “P55_9600bps”. 
7.  Create a new connection with the name “P55_115200bps”. 
8.  Select a the same COM port  used in item 2 and select the Port Settings properties as 
follows:
9.  Select the same General and ASCII properties as item 3. 
10. Close Hyperterminal session, answering “Yes” to close current connection and “Yes” to 
save session “P55_115200bps”. 
�� To start updating session, click over “P55_9600bps” icon that you can find in the “START\All 
programs\Accessories\Communications\HyperTerminal\HyperTerminal”  folder  and  follow  next 
procedure:
1.  Check  the  connection  between  TV  set  and  PC,  sending  a  wrong  command,  as  for 
example: “aaa”. TV set returns an “ERR” label as an syntaxis ERROR (Not correct order 
or sequence). 
24
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
2. Send the command “DWMD” to enter TV set in Download Mode. The TV set answer sending same symbol con-
tinuosly. If this symbol character doesn’t appear, please don’t worry and pass to next step.
3. Close this connection and open “P55_115200bps” connection clicking over the “P55_115200bps” that you can find 
in “START\All programs\Accessories\ Communications\HyperTerminal\HyperTerminal” folder.
4. Using “Transfer\Send file…” menu, select desired file (.bin format) and the transmission protocol (Xmodem) as 
show below.
5. After press “Send” button the updating process starts as follows:
6. When flash update process finishes, the “Flash Programming Complete” label appears in the screen. 
VERY IMPORTANT NOTE:
During the updating time, please don’t use the PC for other purpouses, in order to abolish communication 
problems between TV set and PC. If TV set was not updated properly, the TV won’t have the software to startup 
again, and you must follow the “I2C method” to update another time the TV set.
2.  Send  the  command  “DWMD”  to  enter  TV  set  in  Download  Mode.  The  TV  set  answer 
sending same symbol continuosly. If this symbol character doesn’t appear, please don’t 
worry and pass to next step. 
3.  Close  this  connection  and  open  “P55_115200bps”  connection  clicking  over  the 
“P55_115200bps”  that  you  can  find  in  “START\All  programs\Accessories\ 
Communications\HyperTerminal\HyperTerminal” folder. 
4.  Using “Transfer\Send file…” menu, select desired file (.bin format) and the transmission 
protocol (Xmodem) as show below. 
5.  After press “Send” button the updating process starts as follows: 
6.  When flash update process finishes, the “Flash Programming Complete” label appears 
in the screen.
VERY IMPORTANT NOTE: 
During  the  updating  time,  please  don’t  use  the  PC  for  other  purpouses,  in  order  to  abolish 
communication  problems  between  TV  set  and  PC.  If  TV  set  was  not  updated  properly,  the  TV 
won’t  have  the  software  to  startup  again,  and  you  must  follow  the  “I2C  method”  to  update 
another time the TV set. 
2.  Send  the  command  “DWMD”  to  enter  TV  set  in  Download  Mode.  The  TV  set  answer 
sending same symbol continuosly. If this symbol character doesn’t appear, please don’t 
worry and pass to next step. 
3.  Close  this  connection  and  open  “P55_115200bps”  connection  clicking  over  the 
“P55_115200bps”  that  you  can  find  in  “START\All  programs\Accessories\ 
Communications\HyperTerminal\HyperTerminal” folder. 
4.  Using “Transfer\Send file…” menu, select desired file (.bin format) and the transmission 
protocol (Xmodem) as show below. 
5.  After press “Send” button the updating process starts as follows: 
6.  When flash update process finishes, the “Flash Programming Complete” label appears 
in the screen.
VERY IMPORTANT NOTE: 
During  the  updating  time,  please  don’t  use  the  PC  for  other  purpouses,  in  order  to  abolish 
communication  problems  between  TV  set  and  PC.  If  TV  set  was  not  updated  properly,  the  TV 
won’t  have  the  software  to  startup  again,  and  you  must  follow  the  “I2C  method”  to  update 
another time the TV set. 
2.  Send  the  command  “DWMD”  to  enter  TV  set  in  Download  Mode.  The  TV  set  answer 
sending same symbol continuosly. If this symbol character doesn’t appear, please don’t 
worry and pass to next step. 
3.  Close  this  connection  and  open  “P55_115200bps”  connection  clicking  over  the 
“P55_115200bps”  that  you  can  find  in  “START\All  programs\Accessories\ 
Communications\HyperTerminal\HyperTerminal” folder. 
4.  Using “Transfer\Send file…” menu, select desired file (.bin format) and the transmission 
protocol (Xmodem) as show below. 
5.  After press “Send” button the updating process starts as follows: 
6.  When flash update process finishes, the “Flash Programming Complete” label appears 
in the screen.
VERY IMPORTANT NOTE: 
During  the  updating  time,  please  don’t  use  the  PC  for  other  purpouses,  in  order  to  abolish 
communication  problems  between  TV  set  and  PC.  If  TV  set  was  not  updated  properly,  the  TV 
won’t  have  the  software  to  startup  again,  and  you  must  follow  the  “I2C  method”  to  update 
another time the TV set. 
2.  Send  the  command  “DWMD”  to  enter  TV  set  in  Download  Mode.  The  TV  set  answer 
sending same symbol continuosly. If this symbol character doesn’t appear, please don’t 
worry and pass to next step. 
3.  Close  this  connection  and  open  “P55_115200bps”  connection  clicking  over  the 
“P55_115200bps”  that  you  can  find  in  “START\All  programs\Accessories\ 
Communications\HyperTerminal\HyperTerminal” folder. 
4.  Using “Transfer\Send file…” menu, select desired file (.bin format) and the transmission 
protocol (Xmodem) as show below. 
5.  After press “Send” button the updating process starts as follows: 
6.  When flash update process finishes, the “Flash Programming Complete” label appears 
in the screen.
VERY IMPORTANT NOTE: 
During  the  updating  time,  please  don’t  use  the  PC  for  other  purpouses,  in  order  to  abolish 
communication  problems  between  TV  set  and  PC.  If  TV  set  was  not  updated  properly,  the  TV 
won’t  have  the  software  to  startup  again,  and  you  must  follow  the  “I2C  method”  to  update 
another time the TV set. 
25
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
2. RS-232C Method Description (Tera Term)
The hardware tools requirement are:
1. A Modem-null (Cross type) DB9 female to DB9 female cable.
2. An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ)
3. Make the connections as indicated in the figure:
Software requirements :
To upgrade VCTp software from RS-232C external connector is necessary to use a Tera Term (Pro) free software. 
 
The URL of Tera Term home page is: 
 
http://hp.vector.co.jp/authors/VA002416/teraterm.html
 
(The address may be changed in future)
Tera Term (Pro) supported operating systems:
 
MS-Windows 95 or upper
 
MS-Windows NT 3.5 and 4.0 or upper
Note.- For Windows 3.1 use Tera Term version 1.X.
Copy all the distribution files to an empty floppy disk or temporary directory (for example C:\ TEMP ).
Run SETUP.EXE and follow the instruction given by it.
After the installation, the distribution files are no longer needed, you can delete them or may keep them in the floppy 
disk.
How to use Tera Term Pro :
When the Tera Term (Pro) program is used, it’s necessary to shape some settings. Follows next action to configure 
the connection:
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set
1. Select: 
Serial ⇒ COM X ⇒ O.K. 
26
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
4. Select   
Setup ⇒ Serial port ⇒ O.K. Appear the follow screen:
Select   Setup � serial port � O.K.
Appear a follow screen. 
Select a follow settings:
 Serial port to use: COM x 
       Baud rate: 9600 
       Data: 8 bits 
       Parity : none 
       Stop: 1 bit 
       Flow control: none 
Click O.K. 
2. Select: 
Terminal
3.  Choose the same options as the above picture.
27
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
6. Check the connection between TV set and PC, sending a wrong command, as for example: “aaa”. TV set returns 
an “err” label as an syntaxes ERROR (Not correct order or sequence). 
Send a “DWMD” (capital letters) command to enter TV set in Download Mode.
Change a baud rate to 115200. 
Select: 
Setup ⇒ Baud rate ⇒ 115200 ⇒ O.K.
Select   Setup � serial port � O.K.
Appear a follow screen. 
Select a follow settings:
 Serial port to use: COM x 
       Baud rate: 9600 
       Data: 8 bits 
       Parity : none 
       Stop: 1 bit 
       Flow control: none 
Click O.K. 
5. Select follows settings:
Serial port to use: COM x
Baud rate:  
 9600
Data:  
 
 8 bits
Parity:    
 none
Stop:  
 
 1 bit
Flow control:  
 none
Enter O.K.
Check the connection between TV set and PC, sending a wrong command, as for 
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order 
or sequence).
Send a “DWMD” (capital letters) command to enter TV set in Download Mode. 
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K. 
Select to File � transfer � XMODEM � sent 
Check the connection between TV set and PC, sending a wrong command, as for 
example: “aaa”. TV set returns an “err” label as an syntaxis ERROR (Not correct order 
or sequence).
Send a “DWMD” (capital letters) command to enter TV set in Download Mode. 
Change a baud rate to 115200.
Select setup � baud rate � 115200 � O.K. 
Select to File � transfer � XMODEM � sent 
7. Select:  
File ⇒ Transfer ⇒ XMODEM ⇒ Sent
Choose the file for upgrade and push “open”. 
.
After press “Open” button the upgrade process starts as follows:
28
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
9. After select “Open” the upgrade process starts as follows:
VERY IMPORTANT NOTE:
During the updating time, please don’t use the PC for other purposes, in order to abolish communication prob-
lems between TV set and PC. If TV set was not updated properly, the TV won’t have the software to startup 
again, and you must follow the “I2C method” to update another time the TV set.
8. Choose the file for upgrade and click “Open”.
Choose the file for upgrade and push “open”. 
.
After press “Open” button the upgrade process starts as follows:
When flash update process finishes, the ” Flash programming complete “ label 
appear in the screen , the device automatically go to switch off, and in a few seconds go 
to switch on again. 
Enter in service mode and check the main soft version. 
VERY IMPORTANT NOTE: Seguir con el service manual actual 
10. When flash update process finishes, the ” Flash programming complete “ label appear in the screen , the device 
automatically go to switch off, and in a few seconds go to switch on again.
When flash update process finishes, the ” Flash programming complete “ label 
appear in the screen , the device automatically go to switch off, and in a few seconds go 
to switch on again. 
Enter in service mode and check the main soft version. 
VERY IMPORTANT NOTE: Seguir con el service manual actual 
29
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
3 I2C Method Description
The hardware tools requirement are: 
1. A Parallel port I2C interface with 20 pin to 3 pin cable (Sharp Code: CKIT-0004WJV0).
2 . Make the connections as indicated below:
a. Connect  Parallel port I2C interface to LPT port of the computer.
b. Connect the 20 to 3 pin cable from the I2C interface to the P2306 socket in the main board (XD603).
Before using I2C method is necessary to install Visual I2C software following next procedure.
1. Install Visual I2C release V3.2.3b from file (“Setup_Visual_I2C_v3-2-3b8h.exe”).
•It’s strongly recommended to accept the suggested default folder (“C:\Program Files\Micronas\Visual I2C”).
2. Install Visual I2C VCTp extension from file (“Setup_VI2C_for_VCT6wxyP_v0111.exe”).
•It’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
•During this installation process is possible to install also a complementary software to manage NVM memories . 
This installation is not needed, for this reason uncheck the option when the setup program ask to you. In case of 
installation it’s interesting to change default folder to same as Visual I2C (“C:\Program Files\Micronas\Visual I2C”).
3. Install Parallel driver depending of your Windows version from existing files inside the Visual I2C installation 
folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following next criteria:.
a. Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”).
b. Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”).
c. Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”).
After installing Visual I2C, the new generated file structure should look like this:
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
      To PC
   To P2306
I2C Interface (CKIT-0004WJV0)
 QCNWGA100WJZZ
 QPWBX0004WJZZ
30
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
4. Check installation LPT driver using “C:\Program Files\Micronas\LptDrv\LptDrvTest.exe”. After run this software, if 
LPT driver is installed properly must appear this screen:
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
•If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP
To run VCTp software update program, please click over “VCTP” icon from “START\All programs\Micronas\Visual 
I2C\IC\VCTP” and after Visual I2C finish their starting process click on “TVT” module. As additional method, it’s pos-
sible to create a direct access to “C:\Program Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from 
Windows Desktop.
3.  Install  Parallel  driver  depending  of  your  Windows  version  from  existing  files  inside  the 
Visual I2C installation folder “C:\Program Files\Micronas\Visual I2C\Port_Driver”, following 
next criteria:. 
a.  Windows 98/Me (“Setup_LptDrv_v0104_9x.exe”). 
b.  Windows NT (“Setup_LptDrv_v0104_NT_2000.exe”). 
c.  Windows Xp/2000 (“Setup_LptDrv_v020201_XP_2000.exe”). 
After installing Visual I2C, the new generated file structure should look like this: 
4.  Check  installation  LPT  driver  using  “C:\Program  Files\Micronas\LptDrv\LptDrvTest.exe”.
After run this software, if LPT driver is installed properly must appear this screen: 
�� If the result is not OK, check inside PC bios:  Parallel Port Mode=EPP 
To  run  VCTp  software  updater  program,  please  click  over  “VCTP”  icon  from  “START\All 
programs\Micronas\Visual I2C\IC\VCTP” and after Visual I2C finish their starting process click on 
“TVT”  module.  As  additional  method,  it’s  possible  to  create  a  direct  access  to  “C:\Program 
Files\Micronas\Visual I2C\ic\vct6wxyP\vctq_tvt.vi2c” and launch it from Windows Desktop. 
1
2
3
4
5
7
To start updating process follow next instructions:
1. Set Autoread in ON option.
2. Click on “GO” button.
3. Wait until “40” appears in Bootloader Version field.
4. Close DOS pop up windows pressing any key (“Press any key to continue…”.).
5. Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF.
6. Check in the desired software version is selected in the “Load BinàFlash” option. If it’s not the correct one, 
please double click on the file name and select it. The first time this software is use it’s necessary to confirm write 
Addressing margin as from 0x0 to 0x7ffff.
31
 LC-26GA5E
 LC-32GA5E
  LC-32GA9E/LC-32BV9E
  LC-37GA9E/LC-37BV9E
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
7. Click on the “Load Bin à Flash” to start updating process.
To start updating process follow next instructions. 
1.  Set Autoread in ON option. 
2.  Click on “GO” button. 
3.  Wait until “40” appears in Bootloader Version field. 
4.  Close DOS popup windows pressing any key (“Press any key to continue…”.). 
5.  Click on the “Erase flash” button and wait for a seconds and set the AutoRead to OFF. 
6.  Check in the desired software version is selected in the “Load Bin�Flash” option. If it’s 
not the correct one, please double click on the file name and select it. The first time this 
software is use it’s necessary to confirm writte Addressing margin as from 0x0 to 0x7ffff. 
7.  Click on the “Load Bin � Flash” to start updating process. 
8.  When the updating process finishes, the “Progress” popup window automatically closes. 
If  appears  some  problem  during  the  updating  process  a  error  label  appears  in  the 
filename information line. 
�� If  the  TV  has  problem  to  enters  in  the  “Bootloader  mode”,  it’s  possible  to  force  it  by 
hardware method. This alternative method is described below: 
1.  Switch off TV set or hold VCTp RESET line to GND. 
2.  Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector. 
3.  Switch on TV set  or release VCTp RESET line. 
4.  Release SCL pull down after minimum of 2 seconds. 
5.  Check if VCTp is in bootloader mode with Autoread setting in ON. 
6.  Wait until “40” appears in Bootloader Version field. 
7.  Follow instruction from item 5 on software method. 
�� Sometimes,  depending  on  the  PC  hardware,  the  progress  bar  runs  very  fast  (Normal 
time:  1  minute)  or  some  error  message  appears  in  the  filename  information  line.  This 
means it’s necessary to modify some parameter of LPT port, for this reason select “LPT 
Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “
1” or “2
(normally, these values are the best choice). 
8. When the updating process finishes, the “Progress” pop up window automatically closes. If appears some problem 
during the updating process a error label appears in the filename information line.
If the TV has problem to enters in the “Bootloader mode”, it’s possible to force it by hardware method. This alternative 
method is described below:
1.Switch off TV set or hold VCTp RESET line to GND.
2.Pull down SCL line (pin 1) to GND (pin 3) in P2306 connector.
3.Switch on TV set  or release VCTp RESET line.
4.Release SCL pull down after minimum of 2 seconds.
5.Check if VCTp is in bootloader mode with Autoread setting in ON.
6.Wait until “40” appears in Bootloader Version field.
7.Follow instruction from item 5 on software method.
Sometimes, depending on the PC hardware, the progress bar runs very fast (Normal time: 1 minute) or some error mes-
sage appears in the filename information line. This means it’s necessary to modify some parameter of LPT port, for this 
reason select “LPT Preferences” on the “File\Preferences…” menu and increase Delay from “0” to “1” or “2” (normally, 
these values are the best choice).
RS-232C METHOD DESCRIPTION. 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
Before  using  RS-232C  updating  method  is  necessary  to  configure  a  Terminal  PC  software. 
HyperTerminal  has  been  selected  as  a  Terminal  software  because  it’s  include  in  all  Windows 
versions  as  an  accessory,  and  you  can  find  it  inside  “Accessories\Communications”  folder.  For 
this reason, please follow carefully the next steps: 
1.  First  time  HyperTerminal  is  used,  it’s  necessary  to 
configure some settings. Follows next action to configure 
two  connection:  low  speed  (9600bps)  and  high  speed 
(115200bps).
2.  Create a New Connection file with name “P55_9600bps”. 
3.  Select  a  free  COM  port    and  select  the  Port  Settings 
properties as follows: 
Computer 
TV set

Download Sharp LC-37GA9EK (serv.man7) Service Manual (Repair Manual)

Here you can view online and download Sharp LC-37GA9EK (serv.man7) Service Manual in PDF. LC-37GA9EK (serv.man7) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp LC-37GA9EK (serv.man7) LCD. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.