ES 150PW (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL ES 150PW (serv.man5) EMC - CB Certificate online

 
Page 9 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Thin sheet insulation with a 
thickness of 0.10 mm. in mains 
transformer and TIW in TR1
 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
 P 
Double insulation between conductors connected to 
the mains and accessible parts.  
Primary wires are double  
insulated.  
8.10 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
No secondary wires can come 
into contact with primary parts. 
8.11 
Detaching of wires  
 
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No risk of any wire becoming 
detached. 
N/A 
 
Vibration test carried out .........................................: 
No need, see above 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 P 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
In Standby transformer 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
Mains Plug/connector 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
 
N/A 
8.21 
Bridging components comply with clause 14  
C15 (over relay contacts) 