Page 5 of 58 
Report No.: 1009950  
 
TRF No. IEC60065J 
Test item particulars: 
 
Classification of installation and use............................ : Class II 
Supply connection ....................................................... : Appliance inlet (AC power cord set) 
...................................................................................... :  
...................................................................................... :  
Possible test case verdicts: 
 
- test case does not apply to the test object .................: N/A 
- test object does meet the requirement.......................: P (Pass) 
- test object does not meet the requirement.................: F (Fail) 
Testing.: 
 
Date of receipt of test items ..........................................: 22 January 2010 
Date(s) of performance of tests ....................................: 1 February – 10 May 2010 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report, a point is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
 
General product information: 
This test report also includes model ES150PW/230. Model ES150P/230 and ES150PW/230 are 
similar. Main differences are that ES150PW/230 is provided with a wireless receiver module, 
antenna, cushions and ferrite beads. Also an external transmitter module, model JBLSUBTX1 is 
provided. 
Location of mains switch is different (see photos). ES150PW/230 is provided with an AC inlet including a 
fuse. On ES150P/230 the fuse is located on the inside of the rear panel.  
ES150PW/230 is provided with transformer Huizhou GP Wiring Technology model TD-230-0300A+A. The 
only difference between model TD-230-0300A+A and TD-230-0300A+C is that the first one is provided with 
ferrite cores on the secondary wires. 
The results in this Test Report are partly based on testing of JBL model ES150P/230 with test Report 
ref. No. 707082, and JBL model ES150PW/230, test report 806700. New test results are for the 
addition of a separate standby PCB: 
 
Address of the Factory:  
Dongguan Meiloon Acoustic Equipment Co., Ltd. 
No. 77. Yuanlin Road, Feng Huang Industrial Estate, Tangxia,  
Dongguan, Guangdong Province, 523727, CHINA
 
 