Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N/A
If C is not greater than 0.1 μF no test needed
CXAC1=0.1µF
P
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ..................................................:
5 s (100 or 250 N) ..................................................:
N/A
9.2
No hazard 2s after removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
10.1 Insulation
resistance
(MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................:
insulation ................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ..........................: 48h and 120h (see also
Differences for Singapore)
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
P
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
P
Insulation resistance across REINFORCED
insulation (Class II)
insulation (Class II)
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2 Heating
under
fault
condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
mechanism
P