E 150P - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL E 150P EMC - CB Certificate online

 
Page 7 of 47 
Report No. 702268 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0.5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  ....:   
N/A 
 
Emission limits under fault conditions ....................:   
N/A 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
(See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
any single protective device defeated except those 
of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150
 o
 N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
 P 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
Page of 60