E 150P - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL E 150P EMC - CB Certificate online

 
Page 8 of 47 
Report No. 702268 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 P 
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
This sub-clause is void 
 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0.4 mm (mm) ......................................: 
Primary wires are double 
insulated 
 
Reinforced insulation > 0.4 mm (mm)  ...................: Transformer 
bobbin 
 
Thin sheet insulation used inside the enclosure. 
 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 dielectric 
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 dielectric 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 dielectric 
 N/A 
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and accessible 
parts 
Applies to class I appliances 
N/A 
 
Secondary Wiring: Adequate insulation between 
internal hazardous live parts and conductors 
connected to accessible parts 
 N/A 
8.10 Class 
II 
Wiring: 
(1) Primary: Double insulation between conductors 
connected to the mains and accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and the 
mains 
Live wires are double insulated. 
No secondary wire can come 
into contact with live bare parts.
Page of 60
Display

Click on the first or last page to see other E 150P service manuals if exist.