- Page 22 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.7.2.2
Parts not requiring a fire enclosure
Equipment is class III powered
from a LPS adaptor evaluated
in this test report. Additionally
all components are mounted on
V-1 or better material.
from a LPS adaptor evaluated
in this test report. Additionally
all components are mounted on
V-1 or better material.
P
4.7.3 Materials
—
4.7.3.1
General
Components and materials
have adequate flammability
classification. See appended
table 1.5.1.
have adequate flammability
classification. See appended
table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Fire enclosure not required,
refer to 4.7.2.
refer to 4.7.2.
N/A
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
—
5.1
Touch current and protective conductor current
N/A
5.1.1
General
Class III equipment.
N/A
5.1.2
Equipment under test (EUT)
N/A
5.1.3 Test
circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5 Test
procedure
N/A
5.1.6 Test
measurements
N/A
Test
voltage (V) ................................................. :
—
Measured touch current (mA) ............................ :
—
Max. allowed touch current (mA) ....................... :
—
Measured protective conductor current (mA) .... :
—
Max. allowed protective conductor current (mA) :
—
5.1.7
Equipment with touch current exceeding 3.5 mA
............................................................................ :
N/A
5.1.8
Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
and cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network.
telecommunication network.
N/A