Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.6.1
Top and side openings
No top and side openings, unit
is supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
is supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
N/A
Dimensions (mm) ...............................................:
—
4.6.2
Bottoms of fire enclosures
No bottom openings, unit is
supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
supplied with LPS adaptor
evaluated in this test report and
class III equipment. (refer to
summary of testing)
N/A
Construction
of the bottom ..................................:
—
4.6.3
Doors or covers in fire enclosures
No doors or covers.
N/A
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by adhesive
inside enclosure.
inside enclosure.
N/A
Conditioning temperature (
°C)/time (weeks).......:
—
4.7
Resistance to fire
—
4.7.1
Reducing the risk of ignition and spread of flame
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Equipment is class III
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing) Fire enclosure is not
considered necessary.
equipment, powered from a
LPS adaptor evaluated in this
test report. (refer to summary of
testing) Fire enclosure is not
considered necessary.
N/A
4.7.2.1
Parts requiring a fire enclosure
Refer to 4.7.2.
N/A