DUET 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 45

Read JBL DUET 200 (serv.man3) EMC - CB Certificate online

 
 
- Page 45 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
3.2.1.1 
In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to 
be connected to a mains socket conforming to I.S. 411 by means of that flexible 
cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory 
Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. 
3.2.4 
In Switzerland, for requirements see 3.2.1.1 of this annex. 
3.2.5.1 
In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed
for equipment with a rated current over 10 A and up to and including 13 A. 
3.3.4 
In the United Kingdom, the range of conductor sizes of flexible cords to be 
accepted by terminals for equipment with a RATED CURRENT of over 10 A up to 
and including 13 A is: 
• 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional area. 
4.3.6 
In the United Kingdom, the torque test is performed using a socket outlet complying
with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 
and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: 
Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, except that the 
test of 12.17 is performed at not less than 125 °C. Where the metal earth pin is 
replaced by an Insulated Shutter Opening Device (ISOD), the requirements of 
clauses 22.2 and 23 also apply. 
4.3.6 
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such 
devices shall comply with Statutory Instrument 526:1997 - National Standards 
Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets 
for domestic use) Regulations, 1997. 
5.1.7.1 
In FinlandNorway and Sweden TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for the following equipment: 
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that  
 
○ 
is intended to be used in a RESTRICTED ACCESS LOCATION where
 
 
equipotential bonding has been applied, for example, in a  
  telecommunication 
centre; 
and 
 
○ 
has provision for a permanently connected PROTECTIVE EARTHING 
  CONDUCTOR; 
and 
 
○ 
is provided with instructions for the installation of that conductor by a 
  SERVICE 
PERSON; 
• STATIONARY PLUGGABLE EQUIPMENT TYPE B; 
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT. 