DUET 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 44

Read JBL DUET 200 (serv.man3) EMC - CB Certificate online

 
 
- Page 44 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
3.2.1.1 
In Switzerland, supply cords of equipment having a RATED CURRENT not 
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 
60884-1 and one of the following dimension sheets: 
SEV 6532-2.1991   Plug Type 15  
3P+N+PE   250/400 V, 10 A  
SEV 6533-2.1991   Plug Type 11  
L+N    
250 V, 10 A 
SEV 6534-2.1991   Plug Type 12  
L+N+PE  
250 V, 10 A 
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 
A plug and socket-outlet system is being introduced in Switzerland, the plugs of 
which are according to the following dimension sheets, published in February 1998:
SEV 5932-2.1998   Plug Type 25  
3L+N+PE   230/400 V, 16 A 
SEV 5933-2.1998   Plug Type 21  
L+N    
250 V, 16 A 
SEV 5934-2.1998   Plug Type 23  
L+N+PE  
250 V, 16 A 
3.2.1.1 
In Denmark, supply cords of single-phase equipment having a rated current not 
exceeding13 A shall be provided with a plug according to the Heavy Current 
Regulations, Section 107-2-D1. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are 
intended to be used in locations where protection against indirect contact is required
according to the wiring rules shall be provided with a plug in accordance with 
standard sheet DK 2-1a or DK 2-5a. 
If poly-phase equipment and single-phase equipment having a RATED CURRENT 
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in 
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
3.2.1.1 
In Spain, supply cords of single-phase equipment having a rated current not 
exceeding 10 A shall be provided with a plug according to UNE 20315:1994. 
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A 
shall be provided with a plug according to UNE-EN 50075:1993. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are 
intended to be used in locations where protection against indirect contact is required
according to the wiring rules, shall be provided with a plug in accordance with 
standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be 
in accordance with UNE-EN 60309-2. 
3.2.1.1 
In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is 
designed to be connected to a mains socket conforming to BS 1363 by means of 
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in 
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by those regulations. 
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug 
conforming to BS 1363 or an approved conversion plug. 
Page of 62