No. 111798
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.2.1.1
In Switzerland, supply cords of equipment having a RATED CURRENT not
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC
60884-1 and one of the following dimension sheets:
SEV 6532-2.1991 Plug Type 15
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC
60884-1 and one of the following dimension sheets:
SEV 6532-2.1991 Plug Type 15
3P+N+PE 250/400 V, 10 A
SEV 6533-2.1991 Plug Type 11
L+N
250 V, 10 A
SEV 6534-2.1991 Plug Type 12
L+N+PE
250 V, 10 A
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16
A plug and socket-outlet system is being introduced in Switzerland, the plugs of
which are according to the following dimension sheets, published in February 1998:
A plug and socket-outlet system is being introduced in Switzerland, the plugs of
which are according to the following dimension sheets, published in February 1998:
SEV 5932-2.1998 Plug Type 25
3L+N+PE 230/400 V, 16 A
SEV 5933-2.1998 Plug Type 21
L+N
250 V, 16 A
SEV 5934-2.1998 Plug Type 23
L+N+PE
250 V, 16 A
N
3.2.1.1
In Denmark, supply cords of single-phase equipment having a rated current not
exceeding13 A shall be provided with a plug according to the Heavy Current
Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is required
according to the wiring rules shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
exceeding13 A shall be provided with a plug according to the Heavy Current
Regulations, Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is required
according to the wiring rules shall be provided with a plug in accordance with
standard sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
N
3.2.1.1
In Spain, supply cords of single-phase equipment having a rated current not
exceeding 10 A shall be provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A
shall be provided with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is required
according to the wiring rules, shall be provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be
in accordance with UNE-EN 60309-2.
exceeding 10 A shall be provided with a plug according to UNE 20315:1994.
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A
shall be provided with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are
intended to be used in locations where protection against indirect contact is required
according to the wiring rules, shall be provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be
in accordance with UNE-EN 60309-2.
N
3.2.1.1
In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is
designed to be connected to a mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by those regulations.
designed to be connected to a mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by those regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug
conforming to BS 1363 or an approved conversion plug.
conforming to BS 1363 or an approved conversion plug.
N