CS680 - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL CS680 EMC - CB Certificate online

 
 
page 5 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
(See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
 N/A 
 
8 CONSTRUCTIONAL 
REQUIREMENTS 
WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
  
8.5 
Class 
Ι equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1a 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
 
Class 
ΙΙ equipment and Class ΙΙ constructions 
within Class 
Ι equipment 
 N/A 
Page of 48