CS680 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 28

Read JBL CS680 (serv.man2) EMC - CB Certificate online

 
Page 24 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
9.1 
Shock Hazard  
 
Under normal operating conditions: > 35Vpk ac / 60V dc 
 
Notes:  Reference Annex D  
 
CLASS I: (single phase) 
 
AC DC 
 
 
 
U1: - 
Vpk 
mA 
rms
 
U1: 
V  
- mA
 
 
 
 
 
 
U2: - 
Vpk 
 
- mA rms
 
 
 
 
 
CLASS II: (single phase)  
 
AC DC 
 
 
 
U1: 0.018V 
pk 
 
- mA rms
 
U1: - 
 
- mA 
 
 
 
 
 
U2: 0.013V 
pk 
 
- mA rms
 
 
- mA
 
 
10.3 
TABLE: Insulation Resistance Measurements 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ)
Between the poles of the circuit directly connected to 
the supply mains. 
>10 Min. 
Reinforced insulation. 
>10 Min. 
 
 
10.3 
TABLE: Electric Strength Measurements 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
Page of 59