Read JBL CS680 (serv.man2) EMC - CB Certificate online
Page 24 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC DC
U1: -
Vpk
-
mA
rms
U1:
-
V
- mA
U2: -
Vpk
- mA rms
CLASS II: (single phase)
AC DC
U1: 0.018V
pk
- mA rms
U1: -
V
- mA
U2: 0.013V
pk
- mA rms
- mA
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between the poles of the circuit directly connected to
the supply mains.
>10 Min.
2
Reinforced insulation.
>10 Min.
4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Between the poles of the circuit directly connected to the
supply mains.
2120V peak
No
Reinforced insulation.
4240V peak
No
Click on the first or last page to see other CS680 (serv.man2) service manuals if exist.