CS680 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 27

Read JBL CS680 (serv.man2) EMC - CB Certificate online

 
Page 23 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
7.1 TABLE: 
temperature 
rise measurements: Conditions 
 
Power consumption in the OFF/Stand-by mode   
 
 
of the functional switch (W) ................................: 0W in OFF mode 
— 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
1 253 50 
0.37 63  9.8  24 
1 2198 50 0.30 46  7.5  14 
1/8 of max non-clipping output 
power (pink noise). Input signal 
connected to ’Line in L/R’ (See 
instructions in OM Excerpt on page 
3)  
 
 
Loudspeaker impedance (Ω) .............................: 4 
— 
 
Several loudspeaker systems 
Built-in speaker 
 
 
Marking of loudspeaker terminals 
 
Temperature Rise dT of Part
 
dT (K) 
Limit dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
Core of transformer                                             
38 
 
 
Inside plastic cover 
18 
 
 
Supply cords (Not under mechanical stress) 
22 
 
 
60 (50)  
Wiring insulation touching D115 
30 
 
 
60 (50) 
Heat sink supported by PCB 
25 
 
 
85 (75) 
PCB, near D115 
25 
 
 
85 (75) 
Heat sink, on rear panel 
20 
 
 
40 (30) 
Rear panel, near AC inlet 
17 
 
 
40 (30) 
Knobs (plastic) 
14 
 
 
50 (40) 
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ............................. :
23 
— 
— 
— 
— 
Ambient temperature t2 (
o
C) ............................. :
25 
— 
— 
— 
— 
Temperature rise dT of winding: 
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
+
×
=


 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Prim. 
winding 
9.210 10.870 44 85 
(75) E 
Sec. winding red-red 
1.1041 
1.275 
38 
85 (75) 
Sec. winding yellow-yellow 
0.555 
0.647 
41 
85 (75) 
Note: Values in parenthesis intended for tropical climates.