Read JBL CS680 (serv.man2) EMC - CB Certificate online
Page 23 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
7.1 TABLE:
temperature
rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode
of the functional switch (W) ................................: 0W in OFF mode
—
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1 253 50
0.37 63 9.8 24
1 2198 50 0.30 46 7.5 14
1/8 of max non-clipping output
power (pink noise). Input signal
connected to ’Line in L/R’ (See
instructions in OM Excerpt on page
3)
power (pink noise). Input signal
connected to ’Line in L/R’ (See
instructions in OM Excerpt on page
3)
Loudspeaker impedance (Ω) .............................: 4
—
Several loudspeaker systems
Built-in speaker
Marking of loudspeaker terminals
-
Temperature Rise dT of Part
dT (K)
Limit dT (K)
Test Condition No.
No 1
No ___
No ___
Core of transformer
38
-
Inside plastic cover
18
-
Supply cords (Not under mechanical stress)
22
60 (50)
Wiring insulation touching D115
30
60 (50)
Heat sink supported by PCB
25
85 (75)
PCB, near D115
25
85 (75)
Heat sink, on rear panel
20
40 (30)
Rear panel, near AC inlet
17
40 (30)
Knobs (plastic)
14
50 (40)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ............................. :
23
—
—
—
—
Ambient temperature t2 (
o
C) ............................. :
25
—
—
—
—
Temperature rise dT of winding:
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
−
−
+
×
=
⎟
⎟
⎠
⎠
⎞
⎜
⎜
⎝
⎝
⎛
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT
(K)
Insulation
class
Prim.
winding
9.210 10.870 44 85
(75) E
Sec. winding red-red
1.1041
1.275
38
85 (75)
E
Sec. winding yellow-yellow
0.555
0.647
41
85 (75)
E