Read JBL AV1 (serv.man2) EMC - CB Certificate online
Report #70112.e1
37-1 Ayer Road
Littleton, MA 01460
Page 10 of 27
Tel: (978) 486-043
Fax: (978) 486-0592
www.entela.com
3. Test
Description/Results
3.1 Radiated
Emissions
3.1.1 Object
The purpose of this test is to measure the radiated electromagnetic emissions generated by the
equipment under test (EUT), pursuant to FCC part 15 and EN55022 Class B requirements. (See
Table 3.1.1-1 for the Class B radiated limits.)
equipment under test (EUT), pursuant to FCC part 15 and EN55022 Class B requirements. (See
Table 3.1.1-1 for the Class B radiated limits.)
3.1.2 Procedure
Testing is performed in an Open Area Test Site. The EUT is placed on a wooden turntable 80 cm
in height. The EUT is centered laterally on the turntable and flush with the rear of the table.
Peripheral equipment is placed on either side of the EUT with a minimum of 10 cm spacing.
(When testing a personal computer system, monitors shall be placed on top of the PC, and the
keyboard and mouse shall be placed in front of the PC towards the front edge of the turntable.)
Excess interface cables are draped over the back edge of the table no closer than 40 cm to the
ground plane.
in height. The EUT is centered laterally on the turntable and flush with the rear of the table.
Peripheral equipment is placed on either side of the EUT with a minimum of 10 cm spacing.
(When testing a personal computer system, monitors shall be placed on top of the PC, and the
keyboard and mouse shall be placed in front of the PC towards the front edge of the turntable.)
Excess interface cables are draped over the back edge of the table no closer than 40 cm to the
ground plane.
The EUT shall be set into operation such that all parts of the system are exercised. This may
require the use of test software designed to exercise the various parts of the system. With the EUT
set into operation, the turntable is rotated over 360 degrees and interface cables are manipulated
to maximize the emissions. The peripherals are not moved during the test. The receiving antenna
is placed at a test distance of 3 or 10 meters from the closest point on the EUT. The antenna
height is varied from 1 to 4 meters, and the polarity of the antenna is switched between vertical
and horizontal such that the received signal is maximized.
require the use of test software designed to exercise the various parts of the system. With the EUT
set into operation, the turntable is rotated over 360 degrees and interface cables are manipulated
to maximize the emissions. The peripherals are not moved during the test. The receiving antenna
is placed at a test distance of 3 or 10 meters from the closest point on the EUT. The antenna
height is varied from 1 to 4 meters, and the polarity of the antenna is switched between vertical
and horizontal such that the received signal is maximized.
3.1.3 Deviations from Test Method
None
3.1.4 Measurement
Uncertainty
A minimum of a 2 dB margin of compliance is recommended for radiated emissions data to verify
passing results. This is recommended to compensate for the measurement uncertainties involved.
passing results. This is recommended to compensate for the measurement uncertainties involved.
Click on the first or last page to see other AV1 (serv.man2) service manuals if exist.