Read JBL AV1 (serv.man2) EMC - CB Certificate online
Report #70112.e1
37-1 Ayer Road
Littleton, MA 01460
Page 9 of 27
Tel: (978) 486-043
Fax: (978) 486-0592
www.entela.com
Table 2.3-1: Test Equipment
Asset #
Description
Model
Serial #
Calibration
Due Date
Radiated/Site 1 - A
145-006
BiLog Antenna
(30 MHz to 2 GHz)
(30 MHz to 2 GHz)
Chase CBL6112A
2284
7-21-05
145-001
Spectrum Analyzer
(9 KHz to 22 GHz)
(9 KHz to 22 GHz)
HP8593E 3543A01976
3-26-05
145-092
EMI Receiver
(9 KHz to 2.9 GHz)
(9 KHz to 2.9 GHz)
HP8542E 6906A00273
11-26-04
145-013
Preamplifier
(150 KHz to 1.3 GHz)
(150 KHz to 1.3 GHz)
HP 8447D
2944A07027
11-5-04
145-082 Cable
Rosenberger
N/A
1-23-05
145-083 Cable
Rosenberger
N/A
1-23-05
145-084 Cable
Rosenberger
N/A
1-23-05
High Frequency Setup/site 1 – B
145-029
Guided Ridged Horn
(1 GHz to 18 GHz)
(1 GHz to 18 GHz)
EMCO 3115
5520
8-5-05
145-020
Preamplifier
(1 GHz to 26.5 GHz)
(1 GHz to 26.5 GHz)
HP 8449B
3008A00948
10-10-04
145-092
EMI Receiver
(9 KHz to 2.9 GHz)
(9 KHz to 2.9 GHz)
H-P85422E 6906A00273
11-26-04
145-084 Cable
(28ft.)
Rosenberger
N/A
1-23-05
145-083 Cable
(10ft.)
Rosenberger
N/A
1-23-05
Conducted/Site1 – C
145-001
Spectrum Analyzer
(9 KHz to 22 GHz)
(9 KHz to 22 GHz)
HP8593E 3543A01976
3-26-05
145-008
LISN: 50
Ω/50µH
Solar
9252-50-R-24-BNC
9252-50-R-24-BNC
971601 8-24-04
145-005
LISN: 50
Ω/50µH
Solar
9252-50-R-24-BNC
9252-50-R-24-BNC
941725 7-30-05
145-075 Cable
RG58/U
N/A
9-22-04
All equipment used for testing has been calibrated according to methods and procedures defined
by the National Institute of Standards and Technology (NIST).
Click on the first or last page to see other AV1 (serv.man2) service manuals if exist.