Read Harman Kardon TU 980 (serv.man2) EMC - CB Certificate online
- Page 5 of 19 -
Report No.
133101
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding 1000V
AC or 1500V DC.
AC or 1500V DC.
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage >35 V,
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................ :
using the network in annex D ................................ :
(see appended table 9.1.1.1)
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15kV
with stored voltages exceeding
15kV
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min.
after surge test for basic and 4 MΩ min. for
reinforced insulation :
after surge test for basic and 4 MΩ min. for
reinforced insulation :
> 100 M
Ω, after surge test
P
10.2
Humidity treatment 48 h or 120 h :
120 h (40
°C).
No impairment
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus.
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
Click on the first or last page to see other TU 980 (serv.man2) service manuals if exist.