TU 980 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon TU 980 (serv.man2) EMC - CB Certificate online

 
 
- Page 5 of 19 - 
 
 
 
 
Report No. 
133101 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation   
No voltages exceeding 1000V 
AC or 1500V DC. 
N/A 
9.1.1.1 
a) Open circuit voltages 
Mains input voltage >35 V, 
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................ : 
(see appended table 9.1.1.1) 
 
c) Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored voltages   
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ 
No part or contact of a terminal 
with stored voltages exceeding 
15kV 
N/A 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min.   
after surge test for basic and 4 MΩ min. for 
reinforced insulation : 
> 100 M
Ω, after surge test   
10.2 
Humidity treatment 48 h or 120 h : 
120 h (40
°C).  
No impairment 
10.3 
Insulation resistance and dielectric strength between 
mains teminals 
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
Class II apparatus. 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
(see appended table 10.3) 
 
Page of 23