Read Harman Kardon TU 980 (serv.man2) EMC - CB Certificate online
- Page 8 of 19 -
Report No.
133101
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0.4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0.4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
Make and break speed independent of speed of
ctuation
V-0 compliance with annex G, G.1.1
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
Make and break speed independent of speed of
ctuation
V-0 compliance with annex G, G.1.1
No mains switch but certified
mains relay provided.
See appended table,
list of critical components.
mains relay provided.
See appended table,
list of critical components.
P
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
Separately approved relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
Measured inrush current (A)
through mains relay: 1.9A
The measured inrush current
value is less than rated inrush
current rating of the mains relay
(rated 100A) - OK.
through mains relay: 1.9A
The measured inrush current
value is less than rated inrush
current rating of the mains relay
(rated 100A) - OK.
P
Socket outlet current marking correct
No socket outlet
N/A