Report No.
133101
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating operation.
(see appended table 7.1)
normal operating operation.
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(ee appended table 7.1)
P
8 CONSTRUCTIONAL
REQUIREMENTS
WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus.
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus has isolating
transformers.
transformers.
P
8.8
Basic or supplementary insulation > 0,4 mm (mm):
N/A
Reinforced insulation > 0,4 mm (mm)
:
a. Transf. bobbin, thickness
> 0.4 mm.
Tested at 3KV, 1 min.
according to cl. 10.3 – OK.
> 0.4 mm.
Tested at 3KV, 1 min.
according to cl. 10.3 – OK.
b. Sheet of insulation in bottom
side of the Main pcb between
primary and metal chassis.
Tested at 3KV, 1 min.
according to cl. 10.3 – OK.
side of the Main pcb between
primary and metal chassis.
Tested at 3KV, 1 min.
according to cl. 10.3 – OK.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
No such thin sheet
N/A
8.21
Bridging components comply with clause 14
C934 capacitor, bridging
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
P