Read Harman Kardon SUB-TS 7 EMC - CB Certificate online
page 24 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
No
.
Component
No.
Fault Test voltage
(V)
Test
time
Fuse No.
Fuse
current
(A)
Result
7 C122 sc 198 3min.
Mains
fuse
≤2.5A Pn = 525-0W, In = 2.5-0A
After 2min. conductors on the
PCB were interrupted, rectifier
D110 broke and mains fuse
opened.
No remarks.
(See next fault case)
8 C122 sc 198
3s Mains
fuse
3.4A
Pn = 640W, In = 3.4A.
Interrupted conductors were
bridged and mains fuse replaced
with T2.5AL:
Original fuse T1.25AL considered
opened due to the high In; test
aborted after 3s.
No remarks.