SUB-TS 7 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 25

Read Harman Kardon SUB-TS 7 EMC - CB Certificate online

 
 
page 21 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W)  ..................... : 0 W in 0FF-position 
 
Operating conditions 
254.4V, 1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
Input signal connected to ’Line Level in L/R’  
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                254.4 
0.43 
79 
21 
 
Loudspeaker impedance (
Ω) ................................ : 4Ω 
 
 Several 
loudspeaker 
systems 
 
 
Marking of loudspeaker terminals 
High Level  in/out 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Supply wiring insulation (Not under mechanical stress.) 
27 
60 
Mains switch  
26 
60 
Mains fuse 
19 
60 
Iron core mains transformer.  
51 
— 
Transformer support (rubber) 
51 
60 
PCB 63 
85 
Buttons (plastic) 
18 
50 
Enclosure (wood) 
24 
60 
Enclosure (metal) near knobs. 
38 
40 
Heat Sink, external (metal) 
40 
40 
Knobs (plastic) 
18 
50 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 21 
 
 
Ambient temperature t2 (
°C) ................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary winding 
9.267 
11.498 
61 
85 
Transformer Secondary winding (Yellow) 
0.701 
0.855 
55 
85 
Transformer Secondary winding (Red) 
1.252 
1.528 
55 
85 
 