AR-200 (serv.man114). 1.Earth Wire Treatment Of The 2nd Cassette Interface Harness. 2.Setting Change Of The Default Value Of The Preheat Transition Time Of AR200 For Europe. 3.Information About The Rear Exterior Mounting Procedure. 4.Default Setting Change Of SIM26-51 Copy Stop Setting . (WHITE) - Sharp Copying Equipment Technical Bulletin (repair manual)

ar-200 (serv.man114) technical bulletin
Model
AR-200 (serv.man114)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
140.35 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / 1.Earth Wire Treatment Of The 2nd Cassette Interface Harness. 2.Setting Change Of The Default Value Of The Preheat Transition Time Of AR200 For Europe. 3.Information About The Rear Exterior Mounting Procedure. 4.Default Setting Change Of SIM26-51 Copy Stop Setting . (WHITE)
File
ar-200-sm114.pdf
Date

Read Sharp AR-200 (serv.man114) Technical Bulletin online

DCE156
Sharp Electronics (UK) Ltd., Technical Services Group
Date:
05 May 2000
Model: AR161/200
Ref.:
055
Colour: White
Page:
1 of 3
1.  EARTH WIRE TREATMENT OF THE 2
ND
 CASSETTE
INTERFACE HARNESS
2.  SETTING CHANGE OF THE DEFAULT VALUE OF THE
PREHEAT TRANSITION TIME OF AR200 FOR EUROPE
3.  INFORMATION ABOUT THE REAR EXTERIOR MOUNTING
PROCEDURE
4.  DEFAULT SETTING CHANGE OF SIM26-51 "COPY STOP
SETTING"
 1.Earth wire treatment of the 2nd cassette interface harness   
1. Model Name:
AR161/200/205, DM2000
2. General:
For the earth wire treatment of the 2nd cassette interface harness of the above models, it
is changed in order that the earth wire does not touch the main motor rotor.
3. Description:
The fixing direction and treatment of the earth wire are as shown in the drawings below.
4. Action:
From production in April 1999
TECHNICAL BULLETIN
DCE156
Sharp Electronics (UK) Ltd., Technical Services Group
 2.Setting change of the default value of the preheat transition time of AR200   
1. Model Name:
AR200 for Europe
2. General:
For the above model, the default value of the preheat transition time setting is changed
from 90 sec to 30 sec.
3. Description:
For the user program, the default setting time of the preheat mode is changed from 90
sec to 30 sec.
4. Action:
From the production in March, 1999
 3.Information about the rear exterior mounting procedure   
1. Model Name:
AR200/205 Series, DM2000
2. General:
For the above models, when the rear exterior is mounted it touches the printer connector
and open/close actuator. This may cause damage to the open/close actuator. Therefore,
we inform you of the rear exterior mounting procedure.
3. Description:
The rear exterior mounting procedure is as follows.
DCE156
Sharp Electronics (UK) Ltd., Technical Services Group
 
Note 1: The open/close actuator and wire for hook of the printer connector must not
be deformed or damaged.
 
Note 2: Disassemble the rear exterior in reverse order to the above.
 4.Default setting change of SIM26-51 "Copy stop setting"   
1. Model Name:
AR161/200/205 Series, DM2000 Series
2. General:
As a result of specification change, the default setting of the SIM26-51 "Copy stop setting"
is changed as follows.
3. Description:
The default settings of Sim26-51 for the Duplex models are as follows.
Simplex model
Duplex model
Except for SEC/SUK
"0: Not stopped"
SEC/SUK
"1: Stopped"
All destinations
"1: Stopped"
Simplex model :
AR161/200, DM2000
Duplex model :   
AR205
4. Action:
AR205: Executed from the 1st unit of the production.
Page of 3
Display

Download Sharp AR-200 (serv.man114) Technical Bulletin

Here you can read online and download Sharp AR-200 (serv.man114) Technical Bulletin in PDF. AR-200 (serv.man114) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-200 (serv.man114) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.