SOUNDSTICKS III (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 74

Read Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate online

IEC 60950-1 (ed.2)
 
 
- Page 4 of 7 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
3.2.3 Permanently 
connected 
equipment has provision 
for connecting and securing a field wiring system 
(i.e. conduit, or leads etc.) per the NEC  
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.2.3 
Permanently connected equipment may have 
terminals or leads not smaller than No. 18 AWG 
(0.82 mm²) and not less than 150 mm in length 
for connection of field installed wiring. 
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.2.3 
If supply wires exceed 60 °C, marking indicates 
use of 75 °C or 90 °C wiring for supply 
connection as appropriate. 
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.2.3 Equipment 
compatible 
with suitable trade sizes of 
conduits and cables. 
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.2.5 
Length of power supply cord limited to between 
1.5 and 4.5 m unless shorter length used when 
intended for a special installation. 
Class III equipment. 
N/A 
3.2.5 
Conductors in power supply cords sized per NEC Class III equipment. 
N/A 
3.2.5 
Power supply cords and cord sets incorporate 
flexible cords suitable for the particular 
application. 
Class III equipment. 
N/A 
3.2.6 
Strain relief provided for non-detachable 
interconnecting cables not supplied by a limited 
power source. 
Class III equipment. 
N/A 
3.2.9 
Adequate wire bending space and volume of field 
wiring compartment required to properly make 
the field connections. 
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.2.9 
Equipment solely for installation in Restricted 
Access Locations using low voltage d.c. systems 
may not need provision for connecting and 
securing a field wiring system when wiring is 
protected from abuse. 
The equipment is not 
permanently connected to the 
mains. 
N/A 
3.3 
Field wiring terminals provided for 
interconnection of units for other then LPS or 
Class 2 circuits also comply with 3.3. 
Class III equipment. 
N/A 
3.3 
Interconnection of units by LPS or Class 2 
conductors may have field wiring connectors 
other than specified in 3.3 if wiring is reliably 
separated 
Class III equipment. 
N/A 
3.3.1 
Terminals for the connection of neutral conductor 
identified by a distinctive white marking or other 
equally effective means 
Class III equipment. 
N/A 
3.3.3 
Wire binding screw terminal permitted for 
connection of No. 10 AWG (5.3 mm²) or smaller 
conductor if provided with upturned lugs, cupped 
washer or equivalent retention. 
Class III equipment. 
N/A 
3.3.4 
Terminals accept US wire sizes (gauge) 
Class III equipment. 
N/A 
3.3.4 
Terminals accept current-carrying conductors 
rated 125% of the equipment current rating. 
Class III equipment. 
N/A 
Page of 85