SoundSticks II - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 17

Read Harman Kardon SoundSticks II EMC - CB Certificate online

 
 
 
 
Page 10 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
Note: 
Model NU40-2100400-I3: 
The measurement is conducted between the output connector and earth. 
Voltage = 0.73 Vpeak, Frequency = 60 Hz, Current = 0.365 mA, Limit = 0.7 mA; 
Voltage = 1.22 Vpeak, Frequency = 60 kHz, Current = 0.61 mA, Limit = 42 mA (0.7 
× 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 0.75 Vpeak, Frequency = 60 Hz, Current = 0.375mA, Limit = 0.7 mA; 
Voltage = 1.4 Vpeak, Frequency = 60 kHz, Current = 0.7 mA, Limit = 42 mA (0.7 x 60). 
Model NU40-2240050-I3: 
The measurement is conducted between the output connector and earth. 
Voltage = 0.88 Vpeak, Frequency = 60 Hz, Current = 0.44 mA, Limit = 0.7 mA; 
Voltage = 1.24 Vpeak, Frequency = 60 kHz, Current = 0.62 mA, Limit = 42 mA (0.7 
× 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 0.96 Vpeak, Frequency = 60 Hz, Current = 0.48mA, Limit = 0.7 mA; 
Voltage = 1.47 Vpeak, Frequency = 60 kHz, Current = 0.735 mA, Limit = 42 mA (0.7 x 60). 
Model NU40-2050400-I3: 
The measurement is conducted between the output connector and earth. 
Voltage = 0.67 Vpeak, Frequency = 60 Hz, Current = 0.335 mA, Limit = 0.7 mA; 
Voltage = 1.1 Vpeak, Frequency = 60 kHz, Current = 0.55 mA, Limit = 42 mA (0.7 
× 60). 
The measurement is conducted between CY1 secondary and earth. 
Voltage = 0.72 Vpeak, Frequency = 60 Hz, Current = 0.36mA, Limit = 0.7 mA; 
Voltage = 1.17 Vpeak, Frequency = 60 kHz, Current = 0.585 mA, Limit = 42 mA (0.7 x 60). 
Page of 105
Display