Read Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate online
Date: 2010-09-27
Page 70 of 71
No.: MH184556
3.2.9
Electrical Fast Transients on AC Supply
Test Requirement:
EN 55020
Test Method:
IEC 61000-4-4
Severity:
Level 2 on AC[
±
1kV]
Performance Criterion Requirement:
B
Temperature:
20.0
o
C
Humidity:
58.0 %
Atmospheric Pressure:
101.0 kPa
Test Date(s):
2009-07-06
Mode of Operation:
All modes
Test Method:
The test was performed in accordance with IEC 61000-4-4.
Test Setup:
The test was performed in accordance with IEC 61000-4-4.
Test Setup:
Burst Generator
EUT
0.1m
10cm height stand
EUT
Capacitive
Coupling Clamp
Coupling Clamp
Signal Cable