MAS 101-102-111 (serv.man5) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 64

Read Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate online

Date: 2010-09-27 
 
Page 62 of 71 
No.:  MH184556 
 
 
   
 
Table 16 –Limits of immunity to ambient electromagnetic fields of FM reception functions of sound 
receivers 
Frequency   
Level   
[MHz] 
[dB(
µ
V/m)] 
0.15 -150 
125 
Except frequency bands: 
 
(fi – 0.5) to (fi + 0.5) 
101 
(fo –0.5) to (fo + 0.5) 
109 
(fim – 0.5) to (fim + 0.5) 
109 
87.5 to 108* 
109 
Except the tuned channel±0.15 
 
* The frequency range 87.5 to 108MHz can be varied depending on the use of the FM frequency 
band on a national basis. 
 
Note: fi intermediate frequency (=10.7MHz) 
 
fo = ft ± fi 
local oscillator frequency 
fim = ft ± 2fi 
image frequency 
ft 
Tuned frequency 
 
 
Where: 
 
 
sign “+” applies when fo>ft 
 
sign “-“ applies when fo<ft 
 
 
Table 19 – Limits of immunity to ambient electromagnetic fields of equipment with audio or video 
functions 
Frequency   
Level   
[MHz] 
[dB(
µ
V/m)] 
0.15 to 150 
125 
 
Results: 
Pass 
Please refer to the following table for individual results. 
Page of 73
Display

Click on the first or last page to see other MAS 101-102-111 (serv.man5) service manuals if exist.