Read Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate online
Date: 2010-09-27
Page 67 of 71
No.: MH184556
Severity Levels for Electrostatic Discharge:
Level
Test Voltage
Test Voltage
Direct & Indirect Contact
Discharge
Air Discharge
1
±
2kV
±
2kV
2
±
4kV
±
4kV
3
±
6kV
±
8kV
4
±
8kV
±
15kV
Results:
Pass
Please refer to the following table for individual details
Individual Results
Location
Discharge Method
Test Voltage
Pass
Failed
HCP
[Horizontal Coupling
Plane]
Plane]
Indirect Contact
±
4kV
VCP
[Vertical Coupling Plane]
Indirect Contact
±
4kV
Enclosure
Direct Contact
±
4kV
30 Metal screws
Direct Contact
±
4kV
Remark:
Calculated measurement uncertainty: 0.4kV
.