Read Harman Kardon HS 500 (serv.man4) EMC - CB Certificate online
page 11 of 70
Ref. No. : JSH006020710-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Measured distance:
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: >4.5mm
240Vrms) —accessible parts /
enclosure: >4.5mm
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
Primary heat sink —accessible
parts / enclosure: >10mm
parts / enclosure: >10mm
L-N before fuse link: 3.7mm
T501: P—S: >6.5mm
T502: P—S: >8.0mm
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4 Creepage
distances
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 5.0mm required
240Vrms) —accessible parts /
enclosure: 5.0mm required
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
Primary heat sink —accessible
parts / enclosure: 7.7mm
required
parts / enclosure: 7.7mm
required
L-N before fuse link: 3.0mm
required
required
T501: P—S: 5.6mm required
T502: P—S: 7.7mm required
Pass
Click on the first or last page to see other HS 500 (serv.man4) service manuals if exist.