HS 500 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon HS 500 (serv.man4) EMC - CB Certificate online

 
 
page 10 of  70 
Ref. No. : JSH006020710-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
Pass 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
Pass 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
  
Pass 
13.2 
Determination of operating voltage 
T501: pin13, 14, 15- pin 5, 6: 
270Vrms, 500Vp 
T502: pin3 - pin 15: 380Vrms, 
580Vp 
Pass 
13.3 Clearances 
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: 4.0mm required 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: 4.2mm 
required 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: 5.1mm 
required 
Primary heat sink —accessible 
parts / enclosure: 5.1mm 
required 
L-N before fuse link:  
2.0mm required 
T501: P—S: 4.2mm required 
T502: P—S: 5.1mm required
 
Pass 
Page of 74