Page 12 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T701 basic insulation
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
T702 basic insulation
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T701 bobbin: 0.75mm min.
T702 bobbin: 0.75mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T701 basic insulation
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
minimum 4.0 mm between
T701 core and primary,
Supplementary insulation
minimum 4.0mm between
T701 core and secondary.
T702 basic insulation
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
minimum 4.0 mm between
T702 core and primary,
Supplementary insulation
minimum 4.0mm between
T702 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T701 bobbin: 0.75mm min.
T702 bobbin: 0.75mm min.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II construction
N/A