                                                                   Page 8 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
8.20 
Switch not fitted in the mains cord 
 
N/A 
8.21 
Bridging components comply with clause 14 
 
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1=1.0Vp  
U2=0.16Vp 
Pass 
 
Discharge not exceeding 45 μC 1μC max. 
Pass 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15Kv 
N/A 
9.1.1.2 
Test with test finger and test probe 
 Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 Pass 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
2.3 mm max. no entering 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
40V max. 
Pass 
 
If C is not greater than 0,1uF no test needed 
 N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N Pass 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
N/A 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
 Pass 
10.2 Humidity 
treatment 48 h or 120 h ........................... : 120h, 40℃, 93%R.H. 
Pass 
Page of 69