Page 16 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
output voltage: output circuit not connected to
earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ................... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
Pass
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
N/A
Not soldered to conductors of a printed circuit
board
board
No. Pass
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
Pass
Wire secured by additional means to the conductor Mating lock connector
Pass
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Mating lock connector, both the
conductor and insulation are
crimped.
conductor and insulation are
crimped.
Pass
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A