AU-A18 (serv.man10). Performance curves and refrigerant pipe installation works - Sharp Air Conditioner Service Manual (repair manual)

au-a18 (serv.man10) service manual
Model
AU-A18 (serv.man10)
Pages
1 Few pages! See other manuals at the bottom of the first or last page.
Size
414.02 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / Performance curves and refrigerant pipe installation works
File
au-a18-sm10.pdf
Date

Read Sharp AU-A18 (serv.man10) Service Manual online

21
AH-AP18CS
AH-AP24CS
AU-A18CS
AU-A24CS
Figure P-1. At Cooling for AH-AP18CS
Figure P-2. At Cooling for AH-AP24CS
REFRIGERANT PIPE INSTALLATION WORKS
Refrigerant pipe length and level difference between the indoor and outdoor units.
The shorter refrigerant pipe, the highter the machine capabillity. Keep the pipe line as short as possible.
If actual pipe length exceeds 7.5m, and refrigerant (R22) 15g per 1m.
PERFORMANCE CURVES
MODEL 
AH-AP24CS
PIPE SIZE
GAS
LIQUID
STANDARD PERMISSIBLE
LENGTH
STANDARD LEVEL
DIFERENCE
1/2"
5/8"
1/4"
1/4"
15m
10m
15m
10m
AH-AP18CS
15000
16000
17000
18000
Cooling capacity(BTU/h)
5.5
(kW)
Power input(W)
11
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
12
13
14
15
2000
Indoor air temp. : 29˚C
Indoor humidity : 39RH%
Indoor fan speed : Hi
Power supply : 60Hz, 220V
4 2 4 4 4 6
16
17
2500
3000
4.5
5.0
21000
22000
23000
24000
Cooling capacity(BTU/h)
(kW)
Power input(W)
7
Outside air temp.(˚C)
Inside Outlet air temp.(˚C)
3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7
3 8 3 9 4 0
8
9
10
11
3000
Indoor air temp. : 29˚C
Indoor humidity : 39RH%
Indoor fan speed : Hi
Power supply : 60Hz, 220V
4 2 4 4 4 6
12
13
3500
6.0
6.5
7.0
Pipe length : 7.5 m
 
Pipe length : 7.5 m
Display

Download Sharp AU-A18 (serv.man10) Service Manual (Repair Manual)

Here you can read online and download Sharp AU-A18 (serv.man10) Service Manual in PDF. AU-A18 (serv.man10) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AU-A18 (serv.man10) Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.