HS 300 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 18

Read Harman Kardon HS 300 (serv.man2) EMC - CB Certificate online

 
 
page 14 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: >0.8mm 
T502 bobbin: >0.8mm
 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: >0.8mm 
T502 bobbin: >0.8mm
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: 
U > 4 Kv (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
Page of 73
Display